Check PRI facility and report to service provider; otherwise no action is needed. If problem persists, contact NSAC Tier III.
7005
PRI B-CH Group Inconsist:
Check PRI facility and report to service provider; otherwise no action is needed. If problem persists, contact NSAC Tier III.
7006
PRI Protocol Mismatch :
A mismatch in the protocol being supplied versus the protocol expected by Merlin Magix.
Inform the service provider to change the administration for this circuit. After the service provider restarts the circuit, verify that all alarms for this slot are cleared.
7401
Trk Uplink Message Error : Communications problems between processor and modules; unrecognized message from module to processor.
Test trunk with single-line telephone. If problem is not in the trunk, replace module with one known to work. If problem is not seen with known working module, replace the module and restart.