| Error Code |
Description |
Action |
| |
|
|
| 7402 |
Loop Control Bit Not Set: No loop current on outgoing call. If error occurs four times consecutively, and if automatic maintenance-busy is enabled with less than 50% maintenance busy, trunk is busied out automatically.
|
Test trunk with single-line telephone. If problem is not in the trunk, replace module with one known to work. If problem is not seen with known working module, replace the module and restart.
|
| |
|
|
| 7403 |
No Loop Current:
Communication problems between module and CO. No loop current. If error occurs four times consecutively, and if automatic maintenance-busy is enabled with less than 50% maintenance busy, trunk is busied out automatically.
|
Test trunk with single-line telephone. If problem is not in the trunk, replace module with one known to work. If problem is not seen with known working module, replace the module and restart.
|
| |
|
|
| 7404 |
Stuck Ringing :
Communication problems between module and CO. If error occurs two times consecutively, trunk is busied out automatically whether or not automatic maintenance-busy is enabled.
|
Test trunk with single-line telephone. If problem is not in the trunk, replace module with one known to work. If problem is not seen with known working module, replace the module and restart.
|
| |
|
|
| 7801 |
Not In Normal Op Mode :
Module not in normal operation mode; reported in background module check.
|
Reset board. If problem persists, check module.
Maintenance-Slot-Slot Number- Reset
|
| |
|
|
| 7802 |
Sanity Int Not Generated: Applies only to modules with extension jacks.
|
Reset board. If problem persists, check module. |