Usually no action. Check T1 facility. If problem persists, contact NSAC Tier III. Maintenance-Slot-Error Events-Current hr
6C0B
Hardware Inoperative :
Hardware not operating properly. If this is the only 100D module or 800 NI-BRI module, or if this is the designated clock module, its TDM bus clock generator was not activated.
A busy-out/ restore or reset/restore may clear problem. If problem persists, contact NSAC Tier III.
6C0C
Bri Loss of Sync :
Service on link has been lost..
Usually none; Check BRI facility. If problem persists, contact NSAC Tier III.
6C0D
Bri Slips > 88 : Slip count > 88. Service on link is still operable.
Usually none; Check BRI facility. If problem persists, contact NSAC Tier III.
6C0E
Bri Net Requested CCRC : Outgoing signal to the network does not have valid framing information. Service on link is still operative.
Usually none; link should return to normal once test is completed. If problem persists, contact NSAC Tier III.
6C0F
Bri Net Deactivate Layer 1 of the link is down. Service on the link has been lost
Usually none; link should return to normal once test is completed. If problem persists, contact NSAC Tier III.
6C10
Bri Net Inv 2B+D LB ACT Service on the link has been lost
Usually none; link should return to normal once test is completed. If problem persists, contact NSAC Tier III.